EasyManua.ls Logo

Epson AcuLaser C2800 - Page 102

Epson AcuLaser C2800
459 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING Engine-related Trouble FIP 102
Confidential
FIP 1-21 TonerCart Error Magenta(M)
Possible parts that caused the error
Troubleshooting
FIP 1-22 TonerCart Error Cyan(C)
Possible parts that caused the error
Troubleshooting
IMAGING CARTRIDGE (M)
CONNECTOR CRUM
(CRUM SENSOR) (M)
HARNESS ASSY CRUM
PWBA MCU
Step Check Yes No
1
Check the installation of the IMAGING
CARTRIDGE (M)
Is the IMAGING CARTRIDGE (M) installed
correctly?
Go to Step [2]. Reinstall the
IMAGING
CARTRIDGE
(M) correctly.
2
Check the installation of the CONNECTOR
CRUM (CRUM SENSOR) (M)
Is the CONNECTOR CRUM (CRUM
SENSOR) (M) installed correctly?
Go to Step [3]. Reinstall the
CONNECTOR
CRUM (CRUM
SENSOR) (M)
correctly.
3
Check the connection of the CONNECTOR
CRUM (CRUM SENSOR) (M)
Check the connection state between
CONNECTOR CRUM (CRUM SENSOR) (M)
and PWBA MCU.
Are P/J312 and P/J31 connected correctly?
Go to Step [4]. Reconnect the
P/J312 and P/J31
correctly.
4
Check the continuity of the HARNESS ASSY
CRUM
Is the continuity between P/J312 <=> P/J31
normal
?
Go to Step [5]. Replace the
HARNESS
ASSY CRUM.
5
Check the CONNECTOR CRUM (CRUM
SENSOR) (M)
Is there any damage to the CONNECTOR
CRUM (CRUM SENSOR) (M)?
Go to Step [6]. Replace the
CONNECTOR
CRUM (CRUM
SENSOR) (M).
(p.280)
6
Check after replacing the IMAGING
CARTRIDGE (M)
Replace the IMAGING CARTRIDGE (M) with
a new one. (p.271)
Does the error still occur after the replacement?
Replace the
PWBA MCU.
(p.343)
End of procedure
IMAGING CARTRIDGE (C)
CONNECTOR CRUM
(CRUM SENSOR) (C)
HARNESS ASSY CRUM
PWBA MCU
Step Check Yes No
1
Check the installation of the IMAGING
CARTRIDGE (C)
Is the IMAGING CARTRIDGE (C) installed
correctly?
Go to Step [2]. Reinstall the
IMAGING
CARTRIDGE (C)
correctly.
2
Check the installation of the CONNECTOR
CRUM (CRUM SENSOR) (C)
Is the CONNECTOR CRUM (CRUM
SENSOR) (C) installed correctly?
Go to Step [3]. Reinstall the
CONNECTOR
CRUM (CRUM
SENSOR) (C)
correctly.
3
Check the connection of the CONNECTOR
CRUM (CRUM SENSOR) (C)
Check the connection state between
CONNECTOR CRUM (CRUM SENSOR) (C)
and PWBA MCU.
Are P/J313 and P/J31 connected correctly?
Go to Step [4]. Reconnect the
P/J313 and P/J31
correctly.
4
Check the continuity of the HARNESS ASSY
CRUM
Is the continuity between P/J313 <=> P/J31
normal
?
Go to Step [5]. Replace the
HARNESS
ASSY CRUM.
5
Check the CONNECTOR CRUM (CRUM
SENSOR) (C)
Is there any damage to the CONNECTOR
CRUM (CRUM SENSOR) (C)?
Go to Step [6]. Replace the
CONNECTOR
CRUM (CRUM
SENSOR) (C).
(p.280)
6
Check after replacing the IMAGING
CARTRIDGE (C)
Replace the IMAGING CARTRIDGE (C) with
a new one. (p.271)
Does the error still occur after the replacement?
Replace the
PWBA MCU.
(p.343)
End of procedure

Table of Contents