AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING Engine-related Trouble FIP 118
Confidential
FIP 1-46 Wrong Toner Yellow(Y)
Possible parts that caused the error
Troubleshooting
FIP 1-47 Wrong Toner Magenta(M)
Possible parts that caused the error
Troubleshooting
IMAGING CARTRIDGE (Y) PWBA MCU
Step Check Yes No
1
Check the installation position
Is the IMAGING CARTRIDGE (Y) installed in
the correct position?
Go to Step [2]. Install the
IMAGING
CARTRIDGE
(Y) in the correct
position.
2
Check after replacing the IMAGING
CARTRIDGE (Y)
Replace the IMAGING CARTRIDGE (Y) with
a new one. (p.271)
Does the error still occur after the replacement?
Replace the
PWBA MCU.
(p.343)
End of procedure
IMAGING CARTRIDGE (M) PWBA MCU
Step Check Yes No
1
Check the installation position
Is the IMAGING CARTRIDGE (M) installed in
the correct position?
Go to Step [2]. Install the
IMAGING
CARTRIDGE
(M) in the correct
position.
2
Check after replacing the IMAGING
CARTRIDGE (M)
Replace the IMAGING CARTRIDGE (M) with
a new one. (p.271)
Does the error still occur after the replacement?
Replace the
PWBA MCU.
(p.343)
End of procedure