AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING Engine-related Trouble FIP 119
Confidential
FIP 1-48 Wrong Toner Cyan(C)
Possible parts that caused the error
Troubleshooting
FIP 1-49 Wrong Toner Black(K)
Possible parts that caused the error
Troubleshooting
IMAGING CARTRIDGE (C) PWBA MCU
Step Check Yes No
1
Check the installation position
Is the IMAGING CARTRIDGE (C) installed in
the correct position?
Go to Step [2]. Install the
IMAGING
CARTRIDGE (C)
in the correct
position.
2
Check after replacing the IMAGING
CARTRIDGE (C)
Replace the IMAGING CARTRIDGE (C) with
a new one. (p.271)
Does the error still occur after the replacement?
Replace the
PWBA MCU.
(p.343)
End of procedure
IMAGING CARTRIDGE (K) PWBA MCU
Step Check Yes No
1
Check the installation position
Is the IMAGING CARTRIDGE (K) installed in
the correct position?
Go to Step [2]. Install the
IMAGING
CARTRIDGE
(K) in the correct
position.
2
Check after replacing the IMAGING
CARTRIDGE (K)
Replace the IMAGING CARTRIDGE (K) with
a new one. (p.271)
Does the error still occur after the replacement?
Replace the
PWBA MCU.
(p.343)
End of procedure

Table of Contents