AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING      Test Print 155
Confidential
4. When the engine starts to print, detach the screwdriver from the circuit pattern.  
A test pattern will be printed in single-sided print mode. (When a duplex unit is 
installed, a test pattern will be printed in duplex print mode.)
5. To check the operation of continuous printing, keep the circuit pattern shorted for 
a while.
6. Secure the COVER OPTION with the two screw knurlings. (See Figure 3-6 
(p.154).)
Figure 3-8.  PWBA MCU Short Circuit Location
Figure 3-9.  Test Pattern
C H E C K
P O I N T
Test print can also be performed by removing the BOARD ASSY, 
MAIN and shorting out the unmounted circuit pattern TPRINT 
(lower left of P10) on the PWBA MCU. See 
Figure 3-8 (p.155). 
 Test print will not be performed unless papers are loaded in the 
standard lower paper cassette or in the MP tray.
 Test print will not be performed if the engine is in an error 
state.
P10 TPRINT