AcuLaser C2800/C2800D/C3800/C3800D Revision C
DISASSEMBLY/REASSEMBLY Disassembly/Reassembly 325
Confidential
HARNESS ASSY INTERLOCK
1. Disconnect the connector (P/J44) of the HARNESS ASSY INTERLOCK on the LVPS.
2. Loosen the clamp attached to the SHIELD LVPS that secures the harness of the HARNESS ASSY
INTERLOCK.
3. Release the harness of the HARNESS ASSY INTERLOCK from the DUCT DRV MAIN.
4. Remove the screw (silver, self-tapping, 16 mm) that secures the HARNESS ASSY INTERLOCK to
the main unit.
5. Remove the HARNESS ASSY INTERLOCK from the main unit.
B
Kmy03064E
2)-1
2)-1
2)-2
1)
3)
4)
5)
HARNESS ASSY
INTERLOCK
DRIVE ASSY MAIN
1. Release the harness of the HARNESS ASSY USB from the DUCT DRV MAIN.
2. Remove the two screws (silver, self-tapping, 10 mm) that secure the BRACKET FUSER to the main unit.
Do not pull the BRACKET FUSER too far from the main unit as they are connected with a
harness.
3. Remove the BRACKET FUSER from the main unit.
4. Release the harness of the DRIVE ASSY MAIN from the DUCT DRV MAIN.
5. Remove the screw (silver, self-tapping, 10 mm) that secures the DRIVE ASSY MAIN to the main unit.
NEXT>>
B
Kmy03058EA
4)
5)
2)
2)
3)
7)
7)
6)-1
6)-2
7)
7)
8)-1
8)-1
8)-2