AcuLaser C2800/C2800D/C3800/C3800D Revision C
DISASSEMBLY/REASSEMBLY      Disassembly/Reassembly 334
Confidential
LVPS
NEXT>>
B
Kmy03065EC
2)-1
4)
2)-1
2)-2
1)
1)
1)
1)
1)
(P44)
(P501)
(P502)
(P503)
(P40)
(P47)
(P48)
(P504)
3)
3)
3)
3)
3)
Handle (ROS ASSY)
Do not remove/install the board in areas where static sparks may be generated.  
(e.g. on a carpet) Be sure to touch a metal part to discharge any static electricity you might 
have before removing/installing the board.
1. Disconnect all the connectors on the LVPS and release the harnesses from the clamps.
2. Remove the clamps that secure the harness of the HARNESS ASSY INTERLOCK and that of the 
HARN ASSY INLET from the SHIELD LVPS.
3. Remove the two screws (silver, self-tapping, 10 mm) and the three screws (silver, 6 mm) that secure 
the SHIELD LVPS to the main unit.
4. Remove the SHIELD LVPS together with the LVPS from the main unit.
 The SHIELD LVPS should be placed underneath the PLATE EARTH as shown in the 
figure.
 Hold down the handle if the undersurface of the SHIELD LVPS interferes the handle of 
the ROS ASSY.