Setting of Remote
Address(Host)
IPv4* ✓ – ✓
IPv6** – ✓✓
Blank ✓✓✓
*1If IPsec is selected for Access Control, you cannot specify in a
prex
length.
*2If IPsec is selected for Access Control, you can select a link-local address (fe80::) but group policy will be disabled.
*3Except IPv6 link local addresses.
Related Information
& “Running Web Cong on a Web Browser” on page 34
References of Service Name on Group Policy
Note:
Unavailable services are displayed but cannot be selected.
Service name Protocol type Local port
number
Remote port
number
Features controlled
Any – – – All services
ENPC UDP 3289 Any port Searching for a scanner from
applications such as Epson Device
Admin and the a scanner driver
SNMP UDP 161 Any port Acquiring and conguring MIB from
applications such as Epson Device
Admin and the Epson scanner driver
WSD TCP Any port 5357 Controlling WSD
WS-Discovery UDP 3702 Any port Searching for WSD scanners
Network Scan TCP 1865 Any port Forwarding scanned data from
Document Capture Pro
Network Push
Scan
TCP Any port 2968 Acquiring job information for push
scanning from Document Capture Pro
Network Push
Scan Discovery
UDP 2968 Any port Searching for a computer from scanner
FTP Data
(Remote)
TCP Any port 20 FTP client (forwarding scanned data)
However this can control only an FTP
server that uses remote port number
20.
FTP Control
(Remote)
TCP Any port 21 FTP client (controlling forwarded
scanned data)
CIFS (Remote) TCP Any port 445 CIFS client (forwarding scanned data
to a folder)
Advanced Security Settings
>
Encrypted Communication Using IPsec/IP Filtering
>
Conguring Group Policy
109