3.
Click Next.
A conrmation message is displayed.
4.
Click OK.
e scanner is updated.
Related Information
& “Running Web
Cong
on a Web Browser” on page 34
IEEE802.1X Network Setting Items
Items Settings and Explanation
IEEE802.1X (Wired LAN) You can enable or disable settings of the page (IEEE802.1X > Basic) for IEEE802.1X (Wired
LAN).
IEEE802.1X (Wi-Fi) The connection status of IEEE802.1X (Wi-Fi) is displayed.
Connection Method The connection method of a current network is displayed.
EAP Type Select an option for an authentication method between the scanner and a RADIUS server.
EAP-TLS You need to obtain and import a CA-signed certicate.
PEAP-TLS
PEAP/MSCHAPv2 You need to congure a password.
EAP-TTLS
User ID Congure an ID to use for an authentication of a RADIUS server.
Enter 1 to 128 1-byte ASCII (0x20 to 0x7E) characters.
Password Congure a password to authenticate the scanner.
Enter 1 to 128 1-byte ASCII (0x20 to 0x7E) characters. If you are using a Windows server as a
RADIUS server, you can enter up to 127 characters.
Conrm Password Enter the password you congured for conrmation.
Server ID You can congure a server ID to authenticate with a specied RADIUS server. Authenticator
veries whether a server ID is contained in the subject/subjectAltName eld of a server
certicate that is sent from a RADIUS server or not.
Enter 0 to 128 1-byte ASCII (0x20 to 0x7E) characters.
Certicate Validation You can set certicate validation regardless of the authentication method. Import the
certicate in CA Certicate.
Anonymous Name If you select PEAP-TLS or PEAP/MSCHAPv2 for EAP Type, you can congure an anonymous
name instead of a user ID for a phase 1 of a PEAP authentication.
Enter 0 to 128 1-byte ASCII (0x20 to 0x7E) characters.
Advanced Security Settings
>
Connecting the Scanner to an IEEE802.1X Network
>
Conguring an IEEE802.
…
112