Maintenance 9. Troubleshooting
No. Message Remedy Note 1 Note 2
7600
GUI Builder.
Cannot execute a GUI Builder statement
from the command window.
7602
GUI Builder.
GSet parameter is too long.
Correct the parameter to the proper
length.
7603
GUI Builder.
Too many parameters for GGet.
Check the number of parameters.
7604
GUI Builder.
Not enough data for GGet statement
variable assignment.
Specify the variable.
7610
GUI Builder.
The event task cannot be executed.
System in pause state and
EventTaskType is Normal.
The system can be operated by
changing EventTaskType to NoPause
7611
GUI Builder.
The event task cannot be executed.
Safeguard is open and EventTaskType is
Normal.
The system can be operated by
changing EventTaskType to
NoEmgAbort
7612
GUI Builder.
The event task cannot be executed.
Estop is active and EventTaskType is not
NoEmgAbort.
The system can be operated by
changing EventTaskType to
NoEmgAbort
7613
GUI Builder.
The event task cannot be executed.
System in error state and EventTaskType
is not NoEmgAbort.
The system can be operated by
changing EventTaskType to
NoEmgAbort
7650
GUI Builder.
Invalid property.
Specify the valid property.
7651
GUI Builder.
Invalid form.
Specify the valid form.
7652
GUI Builder.
Invalid control.
Specify the valid control.
7653
GUI Builder.
The specified form is already open.
Modify the
program to avoid double
launch.
7654
GUI Builder.
Event function does not exist.
Check the function name set for the
event.
7655
GUI Builder.
Item does not exist.
Specify the valid item.
7656
GUI Builder.
Invalid property value.
Check the property value and specify
the valid value.
7700
Security.
Invalid user.
Contact the administrator to register the
user
7701
Security.
Invalid password.
Check the password.
7702
Security.
Permission denied.
Contact the administrator to set
authority.
7703
Security.
Option not active.
Register the options.
7710
Source and destination cannot be the
same.
Specify another destination.
7711 Point file name is used by another robot.
Check the point file name.
7712
Invalid axis specified.
Check whether the specified axis is
valid. Check if the axis is specified
correctly.
RC90 (EPSON RC+ 7.0) Rev.4
186

Table of Contents

Other manuals for Epson RC90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC90 and is the answer not in the manual?

Epson RC90 Specifications

General IconGeneral
BrandEpson
ModelRC90
CategoryController
LanguageEnglish

Related product manuals