Setup & Operation 6. Memory Port
6.3.3 Transfer with E-mail
Follow this procedure to transfer the data by e-mail that was saved to the USB memory.
(1) Insert the USB memory to a PC that supports sending of e-mail.
(2) Make sure that the USB memory has following folders.
B_RC90_serial number_data status was saved
→ Exmaple:B_RC90_12345_
2013-10-29_092951
(3) Send all the folders by e-mail.
Delete files that do not relate to the project before transfer.
This function is used to send the data to the system director and EPSON from the end
users for problem analysis.
6.4 Details of Data
The following data files are created by the Controller status storage function.
Backup.txt Information file
File with information for Controller restore.
CurrentMnp01.PRM Robot
Saves information such as ToolSet.
Saves program and I/O status.
Saves various settings of the Controller.
Saves information of connected robot.
Saves installation information of hardware.
ProjectName.obj OBJ file Result of project build.
Prg file is not included.
GlobalPreserves.dat *1 Global Preserve
Saves values of Global Preserve variables.
WorkQueues.dat WorkQue
Saves information of Queues information of the WorkQue.
MCSRAM.bin
MCSYSTEMIO.bin
MCTABLE.bin
MDATA.bin
SERVOSRAM.bin
operation
All files related to
project except
ProjectName.obj *2
Project
When [Include project files when status exported] check box
is checked in EPSON RC+ 7.0 menu-[Setup]-
[System Configuration]-[Controller]-
[Preference], the project file is stored.
*1 When the Controller firmware version is Ver.1.0.*.*, GlobalPreserves.dat is not stored.
*2 Storage of “All files related to project except ProjectName.obj” can be specified by a setting.
RC90 (EPSON RC+ 7.0) Rev.4 37