Setup & Operation 12. I/O Remote Settings
12.1 I/O Signal Description
Remote function is initially assigned to both input and output from 0 to 7.
To change the function assignment from the initial setting, use EPSON RC+ 7.0.
To use all signals, you will need to add Expansion I/O or Fieldbus I/O board(s).
12.1.1 Remote Input Signals
Remote inputs are used to control the Manipulators and start programs. Certain
conditions must be met before inputs are enabled, as shown in the table below.
To accept external remote inputs, assign the remote function and set remote to the control
device. When external remote input is available, “AutoMode output” turns ON.
Except SelProg”, the signals execute each function when the signal starts in input
acceptance condition. The function executes automatically. Therefore, no special
programming is needed.
When an error occurs, you must execute a Resetto clear the error condition before any
other remote input commands can be executed. Use the Error output” and Reset input
to monitor the error status and clear error conditions from the remote device.
Name Initial Description Input Acceptance Condition (*1)
Start 0
Execute function selected at SelProg.
(*2)
Ready output ON
Error output OFF
EStopOn output OFF
SafeguardOn output OFF
Pause input OFF
Stop input OFF
SelProg1
1
Specify the executing Main function
number. (*2)
SelProg2
2
SelProg4
3
SelProg8
Not Set
SelProg16
Not Set
SelProg32
Not Set
Stop
4
All tasks and commands are stopped.
Pause 5
All tasks are paused. (*3)
Running output ON
Continue 6
Continue the paused task.
Paused output ON
Pause input OFF
Stop input OFF
Reset
7
Reset emergency stop and error. (*4)
Ready output ON
Shutdown
Not set
Terminates the system
ForcePowerLow
(*6)
Not set
Stops all tasks and commands.
Sets the motor power at Low.
The status is Low power mode while
the
input is ON even executing
Power High command.
Any time
This input is acceptable even
AutoMode output is OFF.
SelRobot
Changes the output condition of
MotorsO
n, AtHome, PowerHigh, and
MCalReqd. (*9)
NOTE
RC90 (EPSON RC+ 7.0) Rev.4 59

Table of Contents

Other manuals for Epson RC90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson RC90 and is the answer not in the manual?

Epson RC90 Specifications

General IconGeneral
BrandEpson
ModelRC90
CategoryController
LanguageEnglish

Related product manuals