Maintenance 9. Troubleshooting
(5) The [Device Manager] dialog appears.
Click <Universal Serial Bus controllers> and make sure that EPSON Robot
Controller RC170” is registered.
When EPSON Robot Controller RC170 is registered and located under Universal
Serial Bus controllers in step (5), the development PC and the Controller connect
properly.
If the following error message appears, please contact EPSON.
Cannot connect to controller.
!! Error: 1805, Connection failure, check the controller startup and connection of the
communication cable.
If EPSON Robot Controller RC170 is not located under Universal Serial Bus
controllers but located under Other devices in step (5), refer to Maintenance 9.2.2
When recognized under “Other devices” in Windows Device Manager.