EPSON Stylus Pro 9000 Revision B
Adjustment Summary 108
5.1.3 Adjustment Items
All parts that require adjustment when being replaced are listed in the table
below. You will also find a list of required adjustment procedures along with the
order of those procedures.
Table 5-2. Service Parts & Required Adjustments
Service
Operation
Step
Number
Adjustment Items Refer to
Printhead
replacement 1
2
3
4
5
6
7
8
9
10
<Start the Self-Diagnostic Function>
Capping position adjustment
Head rank input (and initial ink
charge)
Head nozzle check
Head slant adjustment (B/C heads)
Head Height (Linear) adjustment
Bi-D adjustment
Head Gap adjustment
Test print
<Reset the Head unit counter>
<Adjust the carriage cover height>
page 113
page 115
Main Board
replacement
1
2
3
4
5
6
7
8
9
10
11
12
13
<Parameter backup> *1
<Firmware update>
<Self-Diagnostic Function>
Sensor Adjustment
Capping position adjustment
Head rank input (initial ink charge
not necessary)
Bi-D adjustment
Head Gap adjustment
Flush point adjustment (L/R)
Feed adjustment
Top/bottom adjustment
Rear Sensor position adjustment
Test print
<Replace the Waste Ink Pads and clear
the counter>
page 112
page 113
page 115
page 134
CR Motor
replacement
1
2
3
4
5
6
7
<CR Steel belt tension adjustment>
•Required tool: Tension Gauge
<Self-Diagnostic Function>
Capping position adjustment
Bi-D adjustment
Head Gap adjustment
Flush point adjustment (L/R)
Top/bottom adjustment
Test print
page 141
page 113
page 115
PF Motor
replacement
1
2
3
4
5
<CR Steel belt tension adjustment>
•Required tool: Tension Gauge
<Self-Diagnostic Function>
Feed adjustment
Top/bottom adjustment
Rear Sensor adjustment
Test print
page 141
page 113
page 126
Sensor assembly
replacement
PFront
PEdge
1 <Self-Diagnostic Function>
Sensor Adjustment
Top/bottom adjustment
page 113
page 134
page 127
Sensor assembly
replacement
PRear
1 <Self-Diagnostic Function>
Sensor Adjustment
Top/bottom adjustment
page 113
page 134
page 127
Sensor assembly
replacement
PThick
1 <Self-Diagnostic Function>
From the "Test" menu select
"Sensor" and then "Paper
Thickness"
•Required tool: Schema Gauge
page 113
page 143
Sensor assembly
replacement
HP Sensor
1 <Self-Diagnostic Function>
Capping position adjustment
page 113
page 117
Sensor assembly
replacement
Cover R/L
Sensor
1 <Self-Diagnostic Function>
From the "Test" menu select
"Sensor" and then "Cover"
page 113
page 144
Table 5-2. Service Parts & Required Adjustments (cont.)
Service
Operation
Step
Number
Adjustment Items Refer to