EPSON Stylus Pro 9000 Revision B
Disassembly & Assembly Disassembly Flow 94
REMOVING THE P_THICK SENSOR
1. Remove the H-TOP cover (refer to "H Top Cover Removal" on page 74).
2. Disconnect the cable from the connector CN12 on the relay board.
3. Remove the two screws (CP(W) M3x6) securing the sensor assembly, and
remove the P_THICK sensor together with the mount plate.
Figure 4-35. P_THICK sensor removal
REMOVING THE P_REAR SENSOR
1. Remove the upper paper guide (refer to "Upper Paper Guide Removal" on
page 79).
2. Disconnect the cable from the connector CN11 on the C277MAIN board.
3. Remove the one screws (CP(W) M3x6) securing the sensor assembly, and
remove the P_REAR sensor together with the mount plate.
Figure 4-36. P_REAR sensor removal