Corrective Maintenance
5-4 © Essemtec AG Fox Maintenance
0000074/05
/ March 31, 2017
Shutting Down the Machine
If the production is still running, the regular
shutdown stops a running production
automatically.
Overview
Shutdown machine
Shutdown on warning window (different dialog
if production is running).
Shutdown Windows
Note:
Wait until windows and the machine has
shut down completely.
Turn the main switch to 0 (OFF).
This shutdown procedure will halt the machine.
The main switch will switch off the electrical
power supplies. Power between inlet and main
switch is still alive. Compressed air is not
discontinued automatically but can be switched
off at the compressed air maintenance unit
manually.
Locking the Main Switch
To prevent unintentional start of the machine it
is essential to bring on the padlock(s) to the
Main Switch.
A start of the machine may not happen before
all the work on and at the machine has been
finalized and all padlocks are removed.
Disconnect the Machine
Disconnect from electrical power.
Disconnect from compressed air.