DIR911T User Guide
51
ALI baud rate: 1200 Line #1
ANI baud rate: 1200
(pinout: port B pin 1 gnd 5)
CURSOR DONE
Figure 32: Configure ALI/ANI Serial Ports Screen
This screen is used to set the BAUD rate of the ALI and ANI serial ports. The values
supported by the DIR911t are 9600, 4800, 2400, 1200, and 300. Use the encoder to
select the appropriate BAUD rate. Use the CURSOR soft key to select the ALI or ANI
serial port. Use the DONE key to exit the menu.
Centralized Archiving Setup
The centralized archive setup screen is shown in Figure #33.
Centralized Archiving: DISABLED
Server: 127.0.0.1
CURSOR REQ AUTH DONE
Figure 33: Centralized Archive Setup Screen
This screen is used to configure and enable the DIR911t centralized archiving task. Use
the CURSOR key to move between the configuration fields.
The “Centralized Archiving” field is used to enable or disable centralized archiving.
The “Server” field is used to specify the IPv4 or hostname of the centralized archive
destination. Turn the encoder to the desired value and press the encoder to select that
character and move to the next position
The REQ AUTH soft key is used to request authorization from the centralized archiving
server (specified in the server field). Once the configuration fields contain the correct
information, pressing the REQ AUTH will cause the DIR911t to send a message to the
server indicating that it wants to start archiving calls to that server. The user must then,
using the server’s configuration method, indicate that the DIR911t is approved for
centralized archiving to that server. At this point, the DIR911t will connect to the server
and begin archiving calls.