271
MIDSECTION
EXHAUST HOUSING SERVICE
12
Tighten the small adapter to exhaust housing
screws and nuts to a torque of 60 to 84 in. lbs. (7
to 9.5 N·m).
Exhaust Housing Assembly –
3.4 L models
Apply Adhesive 847 to the bottom flange of the
inner exhaust housing. Install a new seal. Apply
Triple-Guard grease to outer seal surface.
Install grommet and water tube in the inner
exhaust housing.
Clean and degrease the adapter housing and
outer exhaust housing mating surfaces with
Cleaning Solvent. Apply Gel-Seal II sealant to the
adapter flange of the exhaust housing.
Place the adapter/inner exhaust housing into the
exhaust housing. Guide the water tube through
the hole in the outer housing.
13691
006984
1. Water tube grommet 006982
13692
006981