Maintenance – Annually (Every 2,000 hours of operation)
94 4812325559EN 2018-02-20
Long lasting intervals
The following instructions should be noticed if there
is the intention of keeping the machine parked over
a month without any usage.
These parameters are applied to long lasting intervals up to six
months.
• For further information on long lasting engine
intervals, refer to CUMMINS Engine Manual.
• Remove the battery from the machine, clean it
externally, check the electrolyte level, and if
necessary, charge it monthly.
• Cover the air filter inlet with a plastic cover and seal it
with adhesive tape.
• The nozzle of the exhaustion pipe should be covered
using the same procedure mentioned above (air filter).
• Refuel completely the tank in order to avoid water
condensation and corrosion.
• Drain the accumulated water on the bottom of the
reservoir.
Caps, plastic
canvas, Hydraulic
cylinder, joints,
etc
• Apply grease on the steering joint, on both cylinder
edges. Cover the cylinder steering rod with grease to
avoid oxidation. Apply grease on the forward/reverse
joint control.
• Check if the tires have at least 3.1 bar (45 PSI)
pressure.
• Lower the cover of the instrument panel, cover the
entire machine with a plastic canvas, without allowing
it to touch the floor. If possible, store the machine in a
shelter place, like a warehouse with stable
temperature.
The instructions above marked with * should be performed one
more time before operating the roller again.
Fig. – Tamping roller protected against