3. Output module type CP−A04−M12−CL
3−12
Festo P.BE−CPEA−CL−EN en 0711a
Status LEDs
Short circuit/overload
output
Next to the actuator connections there is a red LED for each
output. This shows a short circuit or overload at the output.
LED (red)
Operating status Error handling
LED is out
No short circuit/overload · None
LED lights up
Short circuit/overload at
output
· Eliminate short circuit and delete the fault
1)
1)
Fault will not be deleted automatically.
Tab.3/6: Status LED short circuit/overload at output
Reaction to short circuit in the load supply
Short circuit/overload If there is a short circuit/overload, the output module will
switch off the output self−holding and communicate the fault
to the CPI master. When the short circuit has been eliminated,
delete this fault as follows:
· Reset the output (e.g. by user program).