A. Technical appendix
A−6
Festo P.BE−CPEA−CL−EN en 0711a
A.1.3 Technical specifications of the CL output modules
Technical specifications Type CP−A04−M12−CL
General technical data See section A.1.1
Protection class as per EN 60 529; plug con
nector inserted or fitted with protective cap
IP65/I P67
Electrical isolation None
Digital outputs
Configuration
Load capacity per digital output
4 outputs as per IEC 1131−2;
24 V DC positive−switching
0.5 A
Electronic fuse
(short circuit, overload)
Trigger current
Response time
Min. 750 mA
Max. 1.5 ms
Internal current consumption of the elec
tronics via the CP connection
<35 mA
Tab.A/4: Technical specifications type CP−A04−M12−CL