DAD 143.x User Manual Profinet Rev.1.1.1 March 2023 Page 35 of 95
Any other value will set the output to 0.0 .
Note: Setting AT 1 will transmit e.g. the net weight in the format:
• If the net weight is negative, then a '-' (minus) will be sent, else a ' ' (space) will be sent.
• The numerical value of the net weight will be sent as seven digits with leading zeros.
• If the parameter DP is set to zero, then no decimal point will be sent. If DP is different from zero a decimal
point will be inserted in the digit string - but will remain seven characters long.
• The transmission will be terminated with a CR command (0x0D).
8.1.3 LE Last Error List (only for RS 232 connection)
The following list shows the code and meaning of the last error occurred in the DAD143.x.
Protocol index does not exist.
The the sub-index does not exist.
The parameter setting is out of range.
The command cannot be executed because
the TAC protection is ON.
The command is not allowed / unknown.
READ_FROM_WRITE_ONLY_PARAMETER
Reading from a write only parameter.
WRITE_TO_READ_ONLY_PARAMETER
Write to a read only parameter.
The Zeroing function has been disabled.
Zeroing this weight is not permitted.
The electrical weight input is outside the
specifications for the device.
LOAD_CELL_CONNECTION_ERROR
The loadcell(s) electrical inputs is not making
sense.
The reading of this parameter is not stable.
The requested Tare value is outside the
allowed range.
Below you see two examples of occurred errors, using the command LE.
Slave (DAD143.x) responds
Meaning (see above Error List)
Code 1: Protocol index does not exist
Code 12: electrical weight input is
outside the specs, e.g. UNDER RANGE