DAD 143.x User Manual Profinet Rev.1.1.1 March 2023 Page 35 of 95
Any other value will set the output to 0.0 .
Note: Setting AT 1 will transmit e.g. the net weight in the format:
If the net weight is negative, then a '-' (minus) will be sent, else a ' ' (space) will be sent.
The numerical value of the net weight will be sent as seven digits with leading zeros.
If the parameter DP is set to zero, then no decimal point will be sent. If DP is different from zero a decimal
point will be inserted in the digit string - but will remain seven characters long.
The transmission will be terminated with a CR command (0x0D).
8.1.3 LE Last Error List (only for RS 232 connection)
The following list shows the code and meaning of the last error occurred in the DAD143.x.
Code
Name
Description
0
NO_ERROR
No error
1
INDEX_DOES_NOT_EXIST
Protocol index does not exist.
2
SUBINDEX_DOES_NOT_EXIST
The the sub-index does not exist.
3
PARAMETER_OUT_OF_RANGE
The parameter setting is out of range.
4
CAL_LOCKED
The command cannot be executed because
the TAC protection is ON.
5
COMMAND_NOT_ALLOWED
The command is not allowed / unknown.
6
READ_FROM_WRITE_ONLY_PARAMETER
Reading from a write only parameter.
7
WRITE_TO_READ_ONLY_PARAMETER
Write to a read only parameter.
8
SYNTAX_ERROR
Syntax error.
9
COMMAND_FAILED
Command failed.
10
ZEROING_DISABLED
The Zeroing function has been disabled.
11
OUT_OF_ZERO_RANGE
Zeroing this weight is not permitted.
12
INPUT_RANGE_EXCEEDED
The electrical weight input is outside the
specifications for the device.
13
LOAD_CELL_CONNECTION_ERROR
The loadcell(s) electrical inputs is not making
sense.
14
READING_NOT_STABLE
The reading of this parameter is not stable.
15
OUT_OF_TARE_RANGE
The requested Tare value is outside the
allowed range.
Below you see two examples of occurred errors, using the command LE.
Master (PC / SPS) sends
Slave (DAD143.x) responds
Meaning (see above Error List)
LE
E:001
Code 1: Protocol index does not exist
LE
E:012
Code 12: electrical weight input is
outside the specs, e.g. UNDER RANGE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flintec DAD143 Series and is the answer not in the manual?

Flintec DAD143 Series Specifications

General IconGeneral
BrandFlintec
ModelDAD143 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals