DAD 143.x User Manual Profinet Rev.1.1.1 March 2023 Page 47 of 95
9.5.3 ST Set Tare
[... see chapter 15.2.7, table bit 3]
This command will activate the net weighing function by storing the current weight value as a tare value.
Range) and NT (No Motion Time)
Slave (DAD143.x) responds
Tare performed / Net operation
be rejected and the DAD143.x will respond with ERR (error).
9.5.4 RT Reset Tare
[... see chapter 15.2.7, table bit 2]
This command resets the tare and the weighing signal returns to gross mode.
Slave (DAD143.x) responds
Tare de-activated / Gross operation
The DAD143.x
9.5.5 SP Set Preset Tare
[Index 0x2100 Sub 0x17]
This command sets a preset tare value.
Slave (DAD 143.X) responds
Tare value 0 (factory default)
9.5.6 TW Window for Automatic Taring
[Index 0x2500 Sub 0x06]
This command defines an amplitude window for the automatic
taring. The setting TW = 100 means, that the system calculates
a new tare value, if the averaged net value of the empty scale
falls within 100 digits of the net zero point. The new tare value
will be averaged over the time period TI (see below). If the
averaged tare value falls outside this window, then the tare
value will not be updated.
Permitted values are from 0 to 65535.
Default setting: TW = 0 [= automatic taring disabled]
Slave (DAD143.x) responds