Home
Flintec
Measuring Instruments
DAD143 Series
Flintec DAD143 Series User Manual
4
of 1
of 1 rating
95 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
DAD 143.x User Manual
Profinet
Rev.1.0.0 October 2022
Page
92
of
95
Additional you s
ee
the M
ain Index and Sub Index.
23.
Use Commands Overv
iew for setup com
mands, here Filter F
L
see below.
Marked are the Cmd Group
F
i
lt
e
r
an
d Cmd Name
Fi
l
t
e
r
V
al
u
e
.
Now you can chang
e the value e.g.
to 5, t
hen
90
92
Table of Contents
Table of Contents
2
Introduction
6
Disclaimer
6
Safety Instructions
7
Specifications
8
Housing & Terminals
9
Terminals Load Cell Connection
9
Load Cell Connection
9
Terminals Power Supply
10
Terminals Service Port RS 232
10
Ethernet Based Ports
10
LED Indicators Terminal 27
11
Seal Switch
11
Logic Inputs & Outputs
12
Analog Outputs
12
Communications and Getting Started
13
Service Port
13
Command Language
13
Baud Rate
13
Getting Started Via Service Port RS 232
13
Getting Started Via Ethernet Based Port, E.g. Use Profinet Viewer
14
Menu Structure for Keybord Setup / Inspection
15
Setup Via Front Panel Keyboard
16
Keyboard Buttons
16
Use of Keyboard Buttons
16
Menu 1 System Zero
17
Menu 2 System Span
18
Menu 3 Display
19
Menu 4 Filter & Motion Detection
20
Menu 5 Analog Output
21
Menu 6 Logic Inputs
22
Menu 7 Logic Outputs
23
Menu 8 Data Communication
23
Factory Default Via Front Panel
26
Error Codes - Shown in the Front Panel Display
26
Examples of Calibration
27
Example 1 Calibration Procedure Using Weights
27
Example 2
29
Setup Via PC / PLC - Command Overview
31
Special Commands of Dad143.X Overview
34
AT Auto Transmit (for Service Port RS 232 Connection, Only)
34
AT Auto Transmit (for PLC Connection)
34
LE Last Error List (Only for RS 232 Connection)
35
Setup Via PC / PLC - Command Descriptions
36
ID, Ih, IV, Is, Sr, Rs
36
ID Get Device Identity
36
Get Firmware Version
36
IS Get Device Status
36
SR Reset Dad143.X Firmware
37
RS Read Serial Number
37
Calibration Commands
37
Cs, Su, Ru, Ft
37
CE Read TAC* Counter / Open Calibration Sequence
37
CI Set Minimum Output Value
38
MR Set Multi-Range / Multi-Interval
38
DS Set Display Step Size
39
DP Set Decimal Point Position
39
Set Calibration Zero Point
39
CG Set Calibration Gain (Span)
39
CV Calibrate Value
39
AV Show Actual Internal MV/V Value
40
ZT Zero Tracking
40
FD Reset to Factory Default Settings
40
ZR Zero Range
40
ZI Initial Zero on / off
40
TM Tare Mode
41
TN Set / Clear Non-Volatile Tare
41
ZN Set / Clear Non-Volatile Zero
41
ZM Zero Mode
41
AZ Absolute Zero Point Calibration (Ecal)
41
AG Absolute Gain Calibration (Ecal)
42
CS Save the Calibration Data
42
SU Save User Setup in EEPROM
42
RU Restore User Setup to Dad143.X
42
FT Firmware Type
42
Motion Detection Commands NR, NT
43
Filter Setting Commands FM, FL, PF, UR
43
FM Filter Mode
43
FL Filter Settings
44
PF Pre-Filter
46
UR Update Rate and Averaging
46
Taring and Zeroing Commands
46
Sz, Rz, Zn, St, Rt, Sp, Tn, Rw, Ti
46
SZ Set System Zero
46
RZ Reset Zero
46
ST Set Tare
47
RT Reset Tare
47
SP Set Preset Tare
47
TW Window for Automatic Taring
47
TI Averaging Time for Automatic Taring
48
Output Commands GG, GN, ON, GT, GS, GW, GA, GH, GM, RM, GO, GV
48
GG Get Gross Value
48
GN Get Net Value
48
GT Get Tare Value
48
GS Get ADC Sample Value
48
OF Output Format for Data String GW
49
GA Get Triggered Average Value
49
GH Get Hold Value
50
TH Trigger Hold Value
50
GM Get Peak Value
50
RM Reset of Peak Value
50
GO Get Peak to Peak Value
50
GV Get Valley Value
50
Auto-Transmit Commands
50
Sg, Sn, Sw, Sa, Sh, Sm, So, Sv
50
SG Send Gross Value Continuously
51
SN Send Net Value Continuously
51
SA Send Triggered Average Value Automatically
51
SH Send Hold Value Continuously
51
SM Send Peak Value Continuously
51
SO Send Peak to Peak Value Continuously
51
Send Valley Value Continuously
51
9.8 Logic Input Functions & Status
52
IN Read Status of the Logic Inputs
52
9.9 Logic Output Commands
52
IO Read / Modify the Status of the Logic Outputs
52
OM Control of the Logic Outputs by the Host Application
53
HT Hold Time for All Setpoints
55
9.10 Communication Setup Commands
55
Ad, Br, DX, Op, Cl, Td
55
AD Device Address
55
BR Baud Rate
55
DX Operation Mode Half-/Full-Duplex
56
OP Open Device
56
CL Close Devices
56
9.11 Analog Output
57
AA Analog Output Base
57
AH Set Analog High Level
57
AL Set Analog Low Level
57
AM Set Analog Output Mode
57
AR Set Analog Reference Value
57
9.12 Save Calibration and Setup
58
Cs, Wp, Ss, As, Gi, Pi
58
CS Save the Calibration Data
58
WP Save the Setup Parameters
58
SS Save Setpoint Parameters
58
AS Save Analog Output Parameters (Only DAD 143.1)
58
GI Get an Image File from the EEPROM
58
PI Download an Image File to the EEPROM
59
9.13 Trigger Commands
59
Sd, Mt, Ga, Te, Tr, Tl, Sa
59
SD Start Delay Time
59
MT Measuring Time
59
GA Get Triggered Average Value
59
TE Trigger Edge
60
TR Software Trigger
60
TL Trigger Level
60
SA Send Triggered Average Value Automatically
60
10 Legal for Trade Applications
61
Access to Metrological Data and Weighing Range Adjustment
61
Protection of the Metrological Data and the Scale Calibration
61
11 Calibration and Calibration Sequence
62
12 Firmware Update Program
63
FU Firmware Update
63
FD Reset to Factory Default Settings
64
Import / Export of Device Settings
64
Service Commands Overview Profinet
65
General System Command
65
PS Protocol Select
65
Ethernet Setup Commands
65
NA Network Address (Read Only)
65
NM Network Mask (Read Only)
65
NG Network Gateway (Read Only)
66
DN Device Name (Read Only)
66
MA MAC Addresses (Read Only)
66
14 Cyclic Data Transfer - Profinet
67
Data Sent from the DAD 143.X to the PLC
67
Data Package Sent from the DAD 143.X
67
Cmdstatus
67
Cmdrddata
68
Data1
68
Data2
68
Qualifier
68
Iodata
68
Datatype1
68
Datatype2
68
Data Sent from the PLC to the DAD 143.X
68
Data Package Sent to the DAD 143.X
68
Cmdwrdata
69
Index
69
Subindex
69
Sendcmd
69
Shortcmd
69
Select1
69
Select2
69
15 Acyclic Data Transfer - Profinet
70
Acyclic Read Example
70
Status Code
71
Appendix Adad 143.X GSDML File
71
18 Instructions for Program
81
Appendix B Parameter List for the DAD 143.X
82
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Flintec DAD143 Series and is the answer not in the manual?
Ask a question
Flintec DAD143 Series Specifications
General
Brand
Flintec
Model
DAD143 Series
Category
Measuring Instruments
Language
English
Related product manuals
Flintec FT-111
137 pages