Specifications
810 Vibration Tester Specifications 2
2-3
810 Vibration Tester Specifications
Specifications are subject to change without notice.
Diagnostic Specifications
Standard Fault Detection......................................Unbalance, Looseness, Misalignment and Bearing Failures
Analysis for............................................................Motors, Fans, Blowers, Belts and Chain Drives, Gearboxes, Couplings, Centrifugal
Pumps, Piston Pumps, Sliding Vane Pumps, Propeller Pumps, Screw Pumps, Rotary
Thread/Gear/Lobe Pumps, Piston Compressors, Centrifugal Compressors, Screw
Compressors, Closed Coupled Machines, Spindles
Machine Rotational Speed Range.......................... 200 RPM to 12,000 RPM
Diagnosis Details ..................................................Fault Severity (Slight, Moderate, Serious, Extreme), Repair Details, Cited Peaks, Spectra
Electrical Specifications
Ranging ..................................................................Automatic
A/D Converter ........................................................4 channel, 24 bit
Usable Bandwidth ...............................................2 Hz to 20 kHz
Sampling .............................................................51.2 Hz
Digital Signal Processing Functions ...................Automatically-configured anti-alias filter, High-pass filter, Decimation, Overlapping,
Windowing, FFT and Averaging
Sampling Rate .......................................................2.5 kHz to 50 kHz
Dynamic Range .....................................................128 dB
Signal-to-Noise Ratio ............................................100 dB
FFT Resolution ......................................................800
Spectral Windows .................................................Hanning
Frequency Units ....................................................Hz, orders, cpm
Amplitude Units.....................................................in/sec, mm/sec, VdB (US), VdB* (Europe)
Non-Volatile Memory.............................................SD micro memory card, 2 GB internal + user-accessible slot for additional storage