116
If applicable, connect the data commu-
nication cables to the inverter again
Secure the inverter to the wall bracket
using two 5x25 mm TX25 screws (4)
Tightening torque = 2.5 Nm
Attach the DATCOM cover (6) and se-
cure using two TX25 screws (5).
Tightening torque = 2.5 Nm
Set the DC disconnector (7) to I
(4)(4)
5
6
(7)
(5) (5)(6)
7
8