Safety and grid requirements
Country setup The "Country Setup" menu area is intended exclusively for installers/service
technicians from authorised specialist companies. The access code must be re-
quested from the national/international Fronius point of contact using an applic-
ation form.
CAUTION!
Risk due to unauthorised access.
Incorrectly set parameters can negatively influence the public grid and/or the in-
verter feeding energy into the grid, and lead to a loss of conformity with the
standard.
The parameters may only be adjusted by installers/service technicians from
authorised specialist companies.
Do not give the access code to third parties and/or unauthorised persons.
WARNING!
Danger due to unauthorised error analyses and repair work.
This can result in serious injury and damage to property.
Fault analyses and repair work on the photovoltaic system may only be car-
ried out by installers/service technicians from authorized specialist compan-
ies in accordance with national standards and guidelines.
The selected country setup for the respective country contains preset paramet-
ers according to the nationally applicable standards and requirements. Depend-
ing on local grid conditions and the specifications of the energy provider, adjust-
ments to the selected country setup may be necessary.
CAUTION!
Risk due to incorrectly set parameters.
Incorrectly set parameters can negatively influence the public grid and/or cause
faults and failures on the inverter, and lead to the loss of standard conformity.
The parameters may only be adjusted by installers/service technicians from
authorised specialist companies.
The parameters may only be adjusted if the energy provider permits or re-
quires this.
Only adjust the parameters taking into account the nationally applicable
standards and/or directives and the specifications of the energy provider.
Feed-in limita-
tion
Energy companies or grid operators may stipulate feed-in limitations for an in-
verter (e.g. max. 70% of kWp or max. 5 kW).
The feed-in limitation takes account of self-consumption by the household be-
fore the power of an inverter is reduced:
-
A custom limit can be set.
-
A Fronius Smart Meter can be connected to the Modbus push-in terminal of
the data communication area at the connections M0/M1- / M0/M1+ for Mod-
bus data.
With the inverter, any PV power that is not allowed to be fed into the public grid
is used to charge the battery instead and/or used by the Fronius Ohmpilot so
123
EN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo GEN24 10.0 and is the answer not in the manual?

Fronius Symo GEN24 10.0 Specifications

General IconGeneral
ModelFronius Symo GEN24 10.0
CategoryInverter
AC nominal output10.0 kW
AC grid frequency50 Hz / 60 Hz
THD< 3 %
Number of MPP trackers2
Protection classIP66
AC Nominal Voltage230 V / 400 V
Operating Temperature Range-25°C to +60°C
Max. apparent AC power10, 000 VA
AC nominal voltage range230 V
DC connection4x DC+ and 4x DC- screw terminals
Maximum AC Power10000 VA
Maximum DC Power15 kW
AC Voltage Range180 - 280 V
CoolingActive cooling
Warranty5 years