Data communication area 33
Internal schematic connection diagram of the IOs 34
Backup power variant - PV Point (OP) 37
General 39
PV Point (OP) 39
Explanation - PV Point (OP) 39
Backup power variant - Full Backup 41
General 43
Prerequisites for backup power mode 43
Transitioning from feeding energy into the grid to backup power mode 43
Transitioning from backup power mode to feeding energy into the grid 43
Backup power and energy saving mode 44
Cabling variants including emergency power circuits and 3-pin separation e.g. Austria or Aus-
tralia
45
Functions 45
Transitioning from feeding energy into the grid to backup power mode 45
Transitioning from backup power mode to feeding energy into the grid 45
All-pin separation cabling variant, e.g. Germany, France 46
Functions 46
Transitioning from feeding energy into the grid to backup power mode 46
Transitioning from backup power mode to feeding energy into the grid 47
All-pin split separation cabling variant (Italy) 48
Functions 48
Transitioning from feeding energy into the grid to backup power mode 48
Transitioning from backup power mode to feeding energy into the grid 49
Installation 51
General 53
Quick-lock system 53
Warning notices on the device 53
System component compatibility 54
Installation location and position 55
Choosing the location of the inverter 55
Choosing the location of third-party batteries 56
Explanation of symbols for the installation position 56
Install the mounting bracket and hang up the inverter 58
Selecting the fixing material 58
Properties of the mounting bracket 58
Do not deform the mounting bracket 58
Fitting the mounting bracket to a wall 58
Installing the mounting bracket on a mast or beam 59
Attaching the mounting bracket to mounting rails 60
Attaching the inverter to the mounting bracket 60
Prerequisites for connecting the inverter 61
Permitted cables 61
Permitted cables for the data communication area 61
Cross section of the AC cable 62
Cross section of the DC cable 63
Maximum alternating current fuse protection 63
Connecting the inverter to the public grid (AC side) 65
Safety 65
Connecting the inverter to the public grid (AC side) 65
Connecting solar module strings to the inverter 68
General comments regarding PV modules 68
Safety 68
PV generator - general information 69
PV generator configuration6 - 10 kW 69
Connecting the solar module strings to the inverter 70
Connecting the battery to the inverter 74
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo GEN24 10.0 and is the answer not in the manual?

Fronius Symo GEN24 10.0 Specifications

General IconGeneral
ModelFronius Symo GEN24 10.0
CategoryInverter
AC nominal output10.0 kW
AC grid frequency50 Hz / 60 Hz
THD< 3 %
Number of MPP trackers2
Protection classIP66
AC Nominal Voltage230 V / 400 V
Operating Temperature Range-25°C to +60°C
Max. apparent AC power10, 000 VA
AC nominal voltage range230 V
DC connection4x DC+ and 4x DC- screw terminals
Maximum AC Power10000 VA
Maximum DC Power15 kW
AC Voltage Range180 - 280 V
CoolingActive cooling
Warranty5 years