Pro Nitrous fuel tables
On the first screen is the configuration that allows setting a delay to start the fuel compensation, based on the
time that the nitrous shot takes to get to the combustion chamber. Since the injectors are closer to the combustion
chamber than the nozzles/foggers, the purpose is that the fuel and nitrous get to the combustion chamber at the very
same time.
After the delay, there are the fuel tables to each stage. You can program the fuel compensation over RPM and it
is calculated considering the main fuel table. In the FTManager software is possible to visualize the total calculated fuel
table.
Nitrous stage cylinder trim and bottle pressure compensation
This is a fuel injection cylinder trim
for the Pro-Nitrous feature. It is important
due to the small differences between
nozzles/foggers sizes, position, pressure
in the nitrous line and other flow
differences. With this feature, you can have
different fuel compensation to each
cylinder and stage.
It is also possible to compensate
the fuel injection considering the bottle pressure. Low bottle pressure requires less fuel.
Nitrous stage timing tables
The
ignition.
After the delay, there are the timing tables to each stage. You can program the timing compensation over RPM
and it is calculated considering the main timing table. In the FTManager software is possible to visualize the total
calculated ignition table.
21.13 Time based output
This feature allows activating an auxiliary output by time, which can be used
to release the parachute, turn on the nitrous or even switch on the torque converter
lockup solenoid.
Also, there are conditions, besides time, to trigger the output. The conditions
are: minimum RPM, minimum TPS, minimum driveshaft RPM and minimum wheel
speed. All this options can be enabled or disabled.
The output signal can be an on/off signal (remaining on while the conditions
are valid) or a pulse (to release the parachute, for instance), which the duration is programmable.
In the on/off mode, when one condition is not valid anymore, the output will turn off.