78
22 Alert settings
22.1 Safe mode RPM limiter
Safe mode protects the engine whenever an alert is activated, limiting
max engine RPM while the alert condition is still happening.
22.2 Alerts
The configuration of alerts allows the programming of sound and
visual alerts whenever a dangerous situation to the engine is detected. It is
possible to setup up to three different actions when any alert is displayed on
the screen.
Alert only: alert is displayed on the screen, but the engine continues to work
normally.
Safe mode: besides the alert displaying on the screen, engine has its max RPM
limited to wha rev
Engine shut off: besides the alert displayed on the screen, engine is
immediately shut off by fuel and ignition cut.
Shift alert: When engine reaches the RPM set on this parameter, an alert can be shown at the dashboard and/or
an auxiliary output can be activated to control an external shift light.
Over rev: setup the RPM for alert and the action the ECU must perform.
Overboost: setup an overboost value to activate the alert and the
action the ECU must perform.
Engine temperature: setup an engine temperature to activate the
alert and the action the ECU must perform.