6.4 Selecting Options
6-25
Chap. 6 SELECTING PERIPHERAL EQUIPMENT
Table 6.10 DC Reactors (DCRs)
DC reactor (DCR) Power
supply
voltage
Applicable
motor
rating
(kW)
Applicable
motor
rating
(HP)
Inverter type
Type
Rated current
(A)
Inductance
(mH)
Coil resistance
(mΩ )
Generated loss
(W)
0.1 1/8 FRN0001C2S-2 0.8
0.2 1/4 FRN0002C2S-2
DCR2-0.2 1.5 20 660
1.6
0.4 1/2
FRN0004C2S-2
DCR2-0.4 3.0 12 280 1.9
0.75 1
FRN0006C2S-2
DCR2-0.75 5.0 7.0 123 2.8
1.5 2
FRN0010C2S-2
DCR2-1.5 8.0 4.0 57.5 4.6
2.2 3
FRN0012C2S-2
DCR2-2.2 11 3.0 43 6.7
3.7 5
FRN0020C2S-2
DCR2-3.7 18 1.7 21 8.8
5.5 7.5
FRN0025C2S-2
DCR2-5.5 25 1.2 16 14
7.5 10
FRN0033C2S-2
DCR2-7.5 34 0.8 9.7 16
11 15
FRN0047C2S-2
DCR2-11 50 0.6 7.0 27
Three-
phase
200 V
15 20
FRN0060C2S-2
DCR2-15 67 0.4 4.3 27
0.4 1/2 FRN0002C2-4 DCR4-0.4 1.5 50 970 2.0
0.75 1 FRN0004C2-4 DCR4-0.75 2.5 30 440 2.5
1.5 2 FRN0005C2-4 DCR4-1.5 4.0 16 235 4.8
2.2 3 FRN0007C2-4 DCR4-2.2 5.5 12 172 6.8
3.7/4.0 5 FRN0011C2-4 DCR4-3.7 9.0 7.0 74.5 8.1
5.5 7.5 FRN0013C2-4 DCR4-5.5 13 4.0 43 10
7.5 10 FRN0018C2-4 DCR4-7.5 18 3.5 35.5 15
11 15 FRN0024C2-4 DCR4-11 25 2.2 23.2 21
Three-
phase
400 V
15 20 FRN0030C2-4 DCR4-15 34 1.8 18.1 28
0.1 1/8 FRN0001C2-7 DCR2-0.2 1.5 20 660 1.6
0.2 1/4 FRN0002C2-7 DCR2-0.4 3.0 12 280 1.9
0.4 1/2 FRN0004C2-7 DCR2-0.75 5.0 7.0 123 2.8
0.75 1 FRN0006C2-7 DCR2-1.5 8.0 4.0 57.5 4.6
1.5 2 FRN0010C2-7
Single-
phase
200 V
2.2 3 FRN0012C2-7
DCR2-3.7 18 1.7 21 8.8
0.1 1/8 FRN0001C2S-6U DCR2-0.75 5.0 7.0 123 2.8
0.2 1/4 FRN0002C2S-6U DCR2-1.5 8.0 4.0 57.5 4.6
0.4 1/2 FRN0003C2S-6U DCR2-2.2 11 3.0 43 6.7
Single-
phase
100 V
0.75 1 FRN0005C2S-6U DCR2-3.7 18 1.7 21 8.8
Note 1: Generated losses listed in the above table are approximate values that are calculated according to the following
conditions:
- The power source is 3-phase 200 V/400 V 50 Hz with 0% interphase voltage unbalance ratio.
- The power source capacity uses the larger of either 500 kVA or 10 times the rated capacity of the inverter.
- The motor is a 4-pole standard model at full load (100%).
- An AC reactor (ACR) is not connected.
Note 2: A box () in the above table replaces A, C, E, or U depending on shipping destination.
Note 3: A box (
■) in the above table replaces S (Basic type) or E (EMC filter built-in type) depending on the enclosure.