6-32
[ 7 ] Options for 100 V single-phase power supply
An optional 100 V single-phase power supply may be used to operate an inverter designed for a 200 V
3-phase power supply with 100 V single-phase power. Select an option with correct capacity
according to the specifications listed in Table 6.14.
Figure 6.13 Optional Single-Phase 100 V Input Dimensions
Table 6.14 Optional Single-Phase 100 V Input
Type CAPA6-0.2 CAPA6-0.4 CAPA6-0.75
(kW) 0.1 and 0.2 0.4 0.75 Applicable inverter capacity
(HP) 1/8 and 1/4 1/2 1
Rated capacity (kVA) 0.5 1.1 1.8