8-2
8.1.2 Three-phase 400 V series
FRN_ _ _ _C2S-4, where = A, C, E, or U
Item Specifications
Type (FRN_ _ _ _C2S-4) 0002 0004 0005 0007 0011 0013 0018 0024 0030
Nominal applied motor (kW) *
1
( = A ,C or E)
0.4 0.75 1.5 2.2
3.7
(
=A,C)
4.0
(
=E)
5.5 7.5 11 15
Nominal applied motor (HP) *
1
( = U)
1/2 1 2 3 5 7.5 10 15 20
Rated capacity (kVA) *
2
1.3 2.3 3.2 4.8 8.0 9.9 13 18 22
Rated voltage (V) *
3
Three-phase, 380 to 480 V (with AVR function)
Rated current (A)
1.8
(1.5)
*
4
3.1
(2.5)
*
4
4.3
(3.7)
*
4
6.3
(5.5)
*
4
10.5
(9.0)
*
4
13.0 18.0 24.0 30.0
Overload capability
150% of rated current for 1 min.
150% of rated current for 1 min or 200% of rated
current for 0.5 s (for the rated current given in
parentheses)
150% of rated current for 1 min or
200% of rated current for 0.5 s
Output Ratings
Rated frequency (Hz) 50 / 60 Hz
Phases, voltage, frequency Three-phase, 380 to 480 V, 50/60 Hz
Voltage and frequency
variations
Voltage: +10 to -15% (Interphase voltage unbalance: 2 % or less*
5
), Frequency:
+5 to -5%
(w/ DCR) 0.85 1.6 3.0 4.4 7.3 10.6 14.4 21.1 28.8
Rated current
(A) *
6
(w/o DCR) 1.7 3.1 5.9 8.2 13.0 17.3 23.2 33.0 43.8
Input Ratings
Required power supply
capacity (kVA) *
7
0.6 1.1 2.0 2.9 4.9 7.4 10 15 20
Braking torque (%) *
8
100 50 30 20
DC braking
Starting frequency*
9
: 0.0 to 60.0 Hz, Braking time: 0.0 to 30.0 s,
Braking level: 0 to 100%
Braking
Transistor for braking
resistor
Built-in
Applicable safety standards UL508C, EN61800-5-1: 2007
Enclosure IP20 (IEC 60529:1989), UL open type (UL50)
Cooling method Natural cooling Fan cooling
Mass (kg) 1.2 1.3 1.7 1.7 2.5 3.1 3.1 4.5 4.5
Mass (lbs) 2.6 2.9 3.7 3.7 5.5 6.8 6.8 9.8 9.8
*1 Fuji 4-pole standard motors.
*2 Assuming the rated output voltage as 440 V for three-phase 400 V series.
*3 Output voltages cannot exceed the power supply voltage.
*4 The load shall be reduced so that the continuous operating current is the rated current in parentheses or less if the
carrier frequency is set to 3 kHz or above or the ambient temperature exceeds 40°C (104°F).
*5
2004):3-61800IECto(Refer67
(V)voltageaveragephase-Three
(V)eMin.voltag-(V)voltageMax.
(%)unbalancevoltageInterphase ×=
If this value is 2 to 3%, use an optional AC Reactor (ACR).
*6 Estimated value to apply when the inverter is connected to the power supply of 500 kVA (inverter capacity x 10
when the inverter capacity exceeds 50 kVA) and %X = 5%.
*7 Obtained when a DC Reactor (DCR) is used.
*8 Average braking torque when a motor of no load decelerates from 60 Hz. (It varies with the efficiency of the
motor.)
*9 Effective function only in induction motor drive.
Note: A box () in the above table replaces A, C, E, or U depending on the shipping destination.
A: Asia, C: China, E: EC, U: USA