9.2 Details of Function Codes
9-99
Chap. 9 FUNCTION CODES
H50
Non-linear V/f Pattern 1 (Frequency) F04 (Base Frequency 1)
F05 (Rated Voltage at Base Frequency 1)
F06 (Maximum Output Voltage 1)
H51 Non-linear V/f Pattern 1 (Voltage) F04 to F06
H52 Non-linear V/f Pattern 2 (Frequency) F04 to F06
H53 Non-linear V/f Pattern 2 (Voltage) F04 to F06
For details about the setting of the non-linear V/f pattern, refer to the descriptions of F04 to
F06.
H54 ACC/DEC Time (Jogging operation)
H54 specifies the common acceleration and deceleration time for jogging operation.
- Data setting range: 0.00 to 3600 (s)
For details about the jogging operation (JOG), refer to E01 to E03 that assign terminal
commands to digital input terminals [X1] to [X3].
H61 UP/DOWN Control (Initial frequency setting)
H61 specifies the initial reference frequency to be applied at startup of UP/DOWN control
that increases or decreases the reference frequency with the UP/DOWN terminal command.
For details, refer to function codes E01 to E03 that assign terminal commands to digital
input terminals [X1] to [X3].
H63
Low Limiter (Mode selection) F15 (Frequency Limiter, High)
F16 (Frequency Limiter, Low)
For how to set up this function code data, refer to the descriptions of F15 and F16.
H64 Low Limiter (Lower limiting frequency)
H64 specifies the lower limit of frequency to be applied when the current limiter, automatic
deceleration (anti-regenerative control), or overload prevention control is activated.
Normally, it is not necessary to change this data.
- Data setting range: 0.0 to 60.0 (Hz)