9-108
A24
Motor 2 (Slip compensation response time)
P10 (Motor 1, Slip compensation response time)
A25
Motor 2 (Slip compensation gain for braking)
P11 (Motor 1, Slip compensation gain for braking)
A26 Motor 2 (Rated slip frequency) P12 (Motor 1, Rated slip frequency)
A39 Motor 2 Selection P99 (Motor 1 Selection)
A41
Output Current Fluctuation Damping Gain for Motor 2
H80 (Output Current Fluctuation Damping Gain for Motor 1)
A51 Cumulative Run Time of Motor 2 H94 (Cumulative Run Time of Motor 1)
A52 Startup Counter of Motor 2 H44 (Startup Counter of Motor 1)
These function codes listed above apply to the 2nd motor. For details about the 1st and 2nd
motors, refer to the descriptions of E1 to E03 (data = 12), "Select motor 2 / motor 1--
M2/M1."