45
Selecting ramp-soak patterns (Settings: 1 / 2 / 3) (Option)
[Description]
This parameter becomes effective when the ramp-soak
operation is changed from
to
.
Setting range
: Performs 1st to 4th segments.
: Performs 5th to 8th segments.
: Performs 1st to 8th segments.
SV
Time
SV-1
SV-2
SV-3
SV-4
SV-8
SV-5
SV-6
SV-7
4 ramp-soak operations (PTn=1)
4 ramp-soak operations (PTn=2)
8 ramp-soak operations (PTn=3)
[Setting example] Changing the ramp-soak execute type from 1 to 3
[Note]
This parameter is not effective if it is changed during RUN
or HOLD.
Types 1 and 2 cannot run one after another.
Once
to are set,
when the SV limiter is set
the set values of to
are not changed, but
the SV displayed during ramp-soak operation is affected
by the SV limiter.
Press the key once. will be displayed and will be registered for . After that, the
controller will operate in ramp-soak type 3
Press and hold the key for three seconds.
will be displayed.
Press the keys to flicker and to display .
(Repeat the procedure from 3 to 5 to check the set value.)
Press the key once.
The current setting ( ) will be displayed.
Press the key to display .
SEL
SEL
SEL
1.
4.
If you want to display the operation status, press and hold the key for two seconds.
The SV will be displayed on the display area.
If unoperated state continues, the PV will be displayed.
6.
2.
3.
SEL
5.
Display Operating procedure
PV indication
PV indication
SV indication

Table of Contents