Parameters of the third block
0 to 255 (Setting to does not start
the communications function.) (*: 1)
Alarm latch (1: use, 0: not use)
Alarm of error status (1: use, 0: not use)
De-energized output (1: use, 0: not use)
*
*
*
*
*
*
0 to 19 (*: specified by customer
while ordering)
Note 2
0 to 100%FS (*: 0%FS)
0 to 100%FS (*: 100%FS)
0 to 9999 seconds (*: 0)
0 to 9999 seconds (*: 0)
-
-
0 to 50%FS (*: 1)
0 to 50%FS (*: 1)
000 to 111 (*: 000)
000 to 111 (*: 000)
-3.0 to 103.0% (*: -3.0)
-3.0 to 103.0% (*: 103.0)
-3.0 to 103.0% (*: -3.0)
-3.0 to 103.0% (*: 103.0)
0 to 15 (*: 0)
0.001 to 2.000 (*: 1.000)
-50 to 50%FS (*: 0)
-50 to 50%FS (*: 0)
0 to 12 (*: 0=OFF)
0: Odd parity*
1: Even parity
2: No parity
0 to 255 (*: 34)
ON: Performs the RCJ
(Cold junction
compensation).*
OFF: Does not perform the RCJ
(Cold junction compensation).
Specifies control action and output at
the input burn-out.
Sets the lower limit of the SV.
Sets the upper limit of the SV.
Delay time or timer value for alarm 1 relay.
Delay time or timer value for alarm 2 relay.
Sets the hysteresis range of ON and
OFF of alarm 1.
Sets the hysteresis range of ON and
OFF of alarm 2.
Sets the optional functions of alarms 1 and 2.
Sets the lower limit for output 1.
Sets the upper limit for output 1.
Sets the lower limit for output 2.
Sets the upper limit for output 2.
Sets the limit types of outputs 1 and
2 (breaking the limit, or maintained
within the limit).
Displays the value of output 1.
Displays the value of output 2.
Sets the cold junction compensation
function to ON/OFF.
Shifts the zero point of input value.
Shifts the span of input value.
Sets the DI1 operations.
Sets the station No. for
communication.
Sets the parity for communication.
(The baud rate is fixed at 9600bps.
Sets the input type for communicating
with PYP.
Control action
SV (Setting value)
lower limiter
SV (Setting value)
upper limiter
Delay time 1
Delay time 2
Alarm 1 hysteresis
Alarm 2 hysteresis
Alarm 1 options
Alarm 2 options
Lower limit for output 1
Upper limit for output 1
Lower limit for output 2
Upper limit for output 2
Output limit types
Output value (MV)
display
Output value (MV)
display
RCJ (Cold junction
compensation)
setting
PV gradient
User-definable zero
adjustment
User-definable span
adjustment
DI1 (Digital input 1)
operation
Station No.
Parity setting
Input type for PYP
(Color Touch-
Operation Unit)
Retransmission
output type
Retransmission
base scale
Retransmission
span scale
Selecting retransmission output type.
Setting retransmission base scale.
Setting retransmission span scale.
0: PV/ 1: Set point/ 2: Output/
3: Error (* : 0)
(Setting range: -100.0 to 100.0%)
(* : 0.0%)
(Setting range: -100.0 to 100.0%)
(* : 100.0%)
dSP9-16
dSP9-32
dSP9-64
dSP9-128
dSP10-1
dSP10-16
dSP10-32
dSP10-128
dSP11-1
dSP11-4
dSP11-8
dSP11-16
dSP11-32
dSP11-64
dSP11-128
dSP12-1
dSP12-2
dSP12-4
dSP12-8
dSP12-16
dSP12-32
0 to 12 (*: 0=OFF)
Sets the DI2 operations.
DI2 (Digital input 2)
operation
dSP12-64
dSP12-128
dSP13-1
dSP13-2
dSP13-4
dSP13-8
dSP13-16
49
50
50
51
51
53
53
54
54
56
56
56
56
57
58
58
59
60
60
61
61
64
65
66
67
68
68
Parameter
display symbol
P-n1
Sv-L
Sv-H
dLY1
dLY2
A1hy
A2hy
A1oP
A2oP
PLC1
PHC1
PLC2
PHC2
PCUT
oUT1
oUT2
rCJ
GAin
AdJ0
AdJS
di-1
di-2
STno
CoM
PYP
Ao-T
Ao-L
Ao-H
User’s
set value
Reference
page
Parameter name Description
Setting range and factory
default setting (*)
Parameter
mask DSP
Note: The parameters for which * is marked with the page number in
Reference page are related to Remedies of 4 on page 70.
Note 2:The following settings are selected as factory defaults depending on the model you order.
Seventh digit = Y model: 0 Seventh digit = A, C, E model: 4

Table of Contents

Other manuals for Fuji Electric PXR3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Electric PXR3 and is the answer not in the manual?

Fuji Electric PXR3 Specifications

General IconGeneral
BrandFuji Electric
ModelPXR3
CategoryTemperature Controller
LanguageEnglish

Related product manuals