DIMENSIONS
(Unit: mm)
7530
120
21 21
19.5 19.5 19.5 19.5
18
60
83.5
12.5
5 - ø7
Left view Front view Rear view
INSTALLATION
Connection Pattern
z
NOTE:
Connection pattern is different according to type of Indoor unit.
Indoor unit types Connection Pattern
All Cassette type
Pattern A
All Duct type
All Ceiling type
Wall Mounted type Pattern B
Pattern A
z
Connect the end of remote controller cable directly to the exclusive terminal block.
Set the DIP switch (SW1) to "3WIRE" on the PC board of the indoor unit.
* Layout of terminal block and
PC board is varies, depending
on the type of indoor unit.
Terminal block
Functional earthing
(If necessary)
Remote controller
cable
Set to "3WIRE" the
DIP switch (SW1)
Indoor unit
PC board
Y1
Y2
Y3
Black
White
Red
NOTE:
The equipment may fail if it is connected to the outdoor unit or the power supply
terminal block.
Pattern B
z
1) Use a tool to cut off the terminal on the end of the remote controller cable, and then
remove the insulation from the cut end of the cable as shown in Fig. 1. Connect the
remote controller cable and connecting cable as shown in Fig. 2. Be sure to insulate the
connection between the cables.
Remote
controller cable
Insulated
connection
White
Black
20 mm
Red
Connecting
cable
2.giF1.giF
- (05 - 125) -
CONTROL
SYSTEM
CONTROL
SYSTEM