Installing the Support Systems
Figure 24: Fit the left support system in the PRIMECENTER/DataCenter rack
1. Position the left support system in the support bracket (insert retaining bolts) - see (1).
2. Clamp the left-hand support system (2) between the front left support upright and the
support bracket by pressing the support system together, positioning it on the front
support upright and releasing it again. The support system automatically adjusts to the
rack depth.
3. The support system no longer has to be fixed to the front support upright because the
easy lock engages and ensures a secure fit.
4. Insert (3) the safety lock into the easy lock (snap fit).
V
CAUTION!
Ensure that the safety lock has been inserted before the server is inserted!
5. Repeat the above steps for the right-hand support system (with the front and rear right
support uprights).