Installing the ETERNUS CS800 Components Cabling the ETERNUS CS800 System
U41842-J-Z125-1-76 59
Dokuschablonen qua19x24 Version 1.1us für FrameMaker V7.x vom 25.03.2010 © cognitas GmbH 2001-2010
1. April 2010 Stand 11:05.09 Pfad: G:\allgemein\CS800\1000500_FTS-Doku\1000502_GettingStartedGuide\GettingStarted.k06
V
CAUTION!
The LAN cables in DX80 must be plugged into the MNT ports and not into the
RMT ports.
Cabling the Expansion Modules (optional)
1. Connect a power cable to each power supply.
I
It is recommended that you connect each expansion module power cord (two
per module) to a separate AC circuit to ensure system availability in case of a
power failure.
2. Connect each DX80 module with the next one via two SAS cables.
I
The SAS cables MUST be connected exactly as shown in figure 38. Failure to
connect the SAS cables to the correct ports will result in data corruption and/or
potential data loss.
Figure 38: Cabling the DX80 modules