Hardware Description CS800 Basic Storage Module
U41842-J-Z125-1-76 71
Dokuschablonen qua19x24 Version 1.1us für FrameMaker V7.x vom 25.03.2010 © cognitas GmbH 2001-2010
1. April 2010 Stand 11:05.09 Pfad: G:\allgemein\CS800\1000500_FTS-Doku\1000502_GettingStartedGuide\GettingStarted.k07
Table 8: DX80 Indicators and Buttons on the Left Side of the Front Panel (with Front Cover)
Table 9: DX80 Switches on the Left Side of the Front Panel (with Front Cover Removed)
Item Indicator, Button Description
1 POWER LED
(green)
Glows green when the power is turned on.
2 READY LED
(green)
Glows green when device is available for use.
3 FAULT LED
(orange)
Glows orange when an internal device part abnormality has
been detected.
Blinks orange when a device part which needs preventive
replacement has been detected.
4 IDENTIFY LED
(blue)
Not used with CS800.
5 CACHE LED
(green)
Glows green when there is data in the device cache.
Blinks when a power failure has occurred and the cache data is
being saved to flash memory.
6 Power Switch Used to turn the device on and off.
Item Indicator, Button Description
1 AutoPWR Enables the AC Auto-Link Mode
(this function automatically turns on the linked device once AC
power is supplied).
This switch is set to "OFF" as the factory setting.
2 MODE SEL Enables the device power to be turned on via power linkage.
This switch is set to "ON" as the factory setting and should not
be set to "OFF".
3 IP RST IP Reset.
V
Do not use!
Clicking once would switch the IP addresses of the two
controller modules of the storage unit.
Clicking twice in succession within a two second interval would
revert the IP addresses to their factory settings.