7.3 Preparations for Use
Table 7.3 Installation Specifications of the PRIMEPOWER600 Pedestal Server (2/2)
Unit
Top
Side
Service
Area
Rear
Service
Area
Front
Service
Area
819 (*1) (D)
(32 in.)
Unit Side
Item Specification
800 (*3)
(32 in.)
480
(19 in.)
800
(32 in.)
819
(32 in.)
Side
Service
Area
800 (*3)
(32 in.)
Unit Dimensions
(units : mm)
Service Areas
(units : mm)
Unit Front
480 (W)
(19 in.)
650 (H)
(26 in.)
1000 (*2)
(39 in.)
580 (23 in.)
*1: Not including any projections.
*2: If it is possible to move the Server Unit so that 800 mm (32-inch) or more space is available behind
the unit when maintenance is performed, then 200mm (8-inch) of space is adequate is normal use.
However, if optical cables are used, at least 300mm (12- inch) of space will be needed between the
rear of the Unit and the wall.
*3: If it is possible to move the server unit so that the 800mm (32-inch) or more space is available
beside the Unit when maintenance is performed, then no space is required in normal use.
125