EasyManua.ls Logo

Fujitsu Primepower200 - Table 8.2 Installation Specifications of the PRIMEPOWER600 Rackmount (10 U) Server

Fujitsu Primepower200
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 8 PRIMEPOWER600 Rackmount (10U) Server
Take electrostatic prevention measures. Note that some carpets generate static electricity easily
and can cause the PRIMEPOWER600 Rackmount (10U) Server to malfunction.
When moving the PRIMEPOWER600 Rackmount (10U) Server, do not pull on the front cover.
Otherwise, the Server may be damaged.
8.3.2 Installation specifications
Table 8.2 and Table 8.3 show the installation specifications for the PRIMEPOWER600 Rackmount (10U) Server.
Table 8.2 Installation Specifications of the PRIMEPOWER600 Rackmount (10U) Server (1/2)
Item Specification
Weight 108 kg (238.41 lb.) (max.) (*1)
Power Supply
Voltage
Frequency 50/60 Hz (+2 ~ -4%)
Max. Current 19.0 A
Leak Current
Frame Resistance
Temperature Operating
Non-operating
Humidity Operating 20 ~ 80% RH (non-condensing)
Non-operating 8 ~ 80% RH (non-condensing)
Vibration Operating 0.2 G
Non-operating 0.4 G
Noise 55 db(A) (*3)
Form Factor Rackmount (10U)
9.5 A
Single phase
AC100V (
±
10%)
Single phase
AC200V (
±
10%)
²
3.5 mA
²
100
5 ~ 35
û
C (+41 ~ +95 F) (*2)
0 ~ 50
û
C (+32 ~ +122 F)
*1: Include Rack Rail weight.
*2: If the ambient temperature exceeds 35 deg. C (95 deg. F) during operation, a warning message is
displayed. Take steps to rectify the problem immediately.
*3: The indicated noise is the mean value of measurements obtained when the server unit is installed in
an 1800mm (71-inch) rack server in a low-noise anechoic chamber. The actual noise measured at
the installation site may be greater than the indicated value due to background noise and echoes.
148