Loading...
Tools: Removing the system board:
Phillips PH2 / (+) No. 2 screw driver
Replacing the TPM:
Bit screw driver
TPM bit insert
(*)
thin slotted screw driver (2 x 0.4 mm)
(*)
(*)
For Japan:
Dedicated TPM screw driver (CWZ8291A)
TPM module fixing tool (S26361-F3552-L909)
CAUTION
Advise your contact persons that they must provide you with all
recovery keys which belong to the system to restore them in the
TPM later
.
Preliminary steps
"Locating the defective server" on page 43.
"Suspending BitLocker functionality" on page
65.
"Shutting down the server" on page 45.
"Disconnecting the power cord" on page 46.
"Getting access to the component" on page 48.
"Removing the air duct" on page 63.
Removing the defective TPM
Remove the TPM, see "Removing the TPM" on page 299.
Leave the TPM spacer on the system board when removing the defective
TPM.
System board and components
304 Upgrade and Maintenance Manual RX1330 M4