Page #149 background imageLoading...
Page #149 background image
Tools: Phillips PH2 / (+) No. 2 screw driver
The CPU fan is implemented in the heat sink. When the CPU fan is
defective, the heat sink must be replaced.
Preliminary steps
"Unlocking the server" on page 39
.
"Removing the bay cover" on page 40.
"Shutting down the server" on page 41.
"Disconnecting the power cord" on page 42.
"Getting access to the component" on page 43.
"Removing the top HDD cage" on page 46.
Removing the heat sink
Remove the heat sink, see "Removing the heat sink" on page 136.
Remove the residual thermal paste from the CPU surface.
Clean the CPU surface using a lint-free cloth.
Installing the heat sink
Remove the protective cover from the heat sink.
Install the heat sink, see "Installing the heat sink" on page 146.
Concluding steps
"Installing the top HDD cage" on page 52.
"Reassembling" on page 50.
"Connecting the power cord" on page 56.
"Switching on the server" on page 57.
"Installing the bay cover" on page 58.
Processor (CPU)
TX1310 M5 Upgrade and Maintenance Manual 149

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX1310 M5 and is the answer not in the manual?

Fujitsu PRIMERGY TX1310 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX1310 M5
CategoryServer
LanguageEnglish

Related product manuals