Note on network settings recovery
When replacing network controllers or the system board, network
configuration settings in the operating system will be lost and replaced
by default values. This applies to all static IP address and LAN teaming
configurations.
Ensure to note down your current network settings before replacing the
system board.
Preliminary steps
Backup the BIOS settings manually.
"Suspending BitLocker functionality" on page
61.
"Unlocking the server" on page 39.
"Removing the bay cover" on page 40.
"Shutting down the server" on page 41.
"Disconnecting the power cord" on page 42.
Disconnect all external cables.
"Getting access to the component" on page 43.
Remove all memory modules, see "Removing a memory module" on
page 130.
Before removing the memory modules, take a note on the installation
slot number for each memory module. Ensure that you reinstall the
memory modules in the slot they were located before the
replacement.
Remove the heat sink, see "Removing the heat sink" on page
149
.
Leave the CPU on the defective board for now.
System board and components
TX1310 M5 Upgrade and Maintenance Manual 207

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX1310 M5 and is the answer not in the manual?

Fujitsu PRIMERGY TX1310 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX1310 M5
CategoryServer
LanguageEnglish

Related product manuals