U41057-J19-Z146-1-76 July 2004 02TX150S273
Diagnostics Troubleshooting
© Siemens Nixdorf Informationssysteme AG 1995 Pfad: P:\02-systemeinheiten\TX150S2\TX150S2-e\TX150S2-e.k03
Added drive is reported as defective
This error message can occur with the SCSI or with the SATA version, providing
the server has a RAID controller.
RAID controller is not configured for this hard disk drive
The drive was installed with the system switched Off.
Ê Reconfigure the RAID controller for the drive with the corresponding
utility. You will find the Information in the documentation of the RAID
controller.
or
Ê Re-insert the hard disk module with the system switched on into a free
bay.
Further information can be found in the operating manual concerning the RAID
controller.