EasyManua.ls Logo

Fujitsu XG0224 - Loopdetect Interval; Loopdetect Recovery

Fujitsu XG0224
631 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XG Series User's Guide Chapter 5 Command Reference
Loop Detection Information Settings
237
5.11.1.4 loopdetect interval
Function Set a transmission interval of the Loop Detection frame.
Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600
Syntax loopdetect interval <time>
Options
<time>
Transmission interval
Specify a transmission interval of the loop detection frame with a value from 1 to 32767
seconds.
The unit shall be h (hour), m (minute), or s (second).
Use Mode Configuration mode (admin class)
Explanation Specify a transmission interval of the Loop Detection frame.
Default It is assumed that 10 seconds have been specified.
5.11.1.5 loopdetect recovery
Function Set the upper limit of monitoring counter for blocking port recovery.
Available Model XG0224 / XG0448 / XG0440DC / XG0440DCR / XG2600
Syntax loopdetect recovery <count>
Options
<count>
Upper limit of monitoring counter for blocking port recovery, with a decimal value from 1
to 65535.
If the counter is expired without detecting the Loop, the blocking port is set non-
blocking again.
Use Mode Configuration mode (admin class)
Explanation Set the upper limit of monitoring counter for blocking port recovery.
If the counter is expired without detecting the Loop, the blocking port is set non-blocking
again.
If the the Loop is detected, the counter is set 0 agein.
The monitoring interval is specified by "loopdetect interval"command.
Default It is assumed 60 has been specified as the upper limit of monitoring counter.
loopdetect interval 10s
loopdetect recovery 60

Table of Contents

Related product manuals