XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
565
6.1 Verifying the Device Operations
This chapter describes the management of the device.
Hardware status
System status
Log messages
6.1.1 Verifying Hardware Status
Verify the status of hardware by entering the "show system status" command and "show ether media-info" command in the
operation mode (admin class) or the configuration mode (admin class).
The following example shows the information that is displayed when the "show system status" command is entered.
Execution Example
XG0224
When no Expansion Card is installed.
When a CX4 Card is installed.
# show system status
Current-time : Wed Dec 10 06:07:43 2008 ---(1)
Startup-time : Wed Dec 10 06:05:05 2008 ---(2)
restart_cause : power on ---(3)
machine_state : RUNNING ---(4)
power0_state : NORMAL ---(5)
fan0_state : NORMAL ---(6)
inspiration_state : NORMAL ---(7)
phy_state : NORMAL
slot1_state : UNKNOWN
inspiration_temp : 26 C ---(8)
phy_temp : 40 C
slot1_temp : -- C
Slot Information
slot1 : NO_PRESENT ---(9)
# show system status
Current-time : Wed Dec 10 05:55:40 2008 ---(1)
Startup-time : Wed Dec 10 05:52:11 2008 ---(2)
restart_cause : power on ---(3)
machine_state : RUNNING ---(4)
power0_state : NORMAL ---(5)
fan0_state : NORMAL ---(6)
inspiration_state : NORMAL ---(7)
phy_state : NORMAL
slot1_state : UNKNOWN
inspiration_temp : 25 C ---(8)
phy_temp : 40 C
slot1_temp : -- C
Slot Information
slot1 : SJ10GCX4Z ---(9)