FC4 / FC4 Ex (HS) connected with Mobility Server
94
GB
Use of an explosion-proof unit without a clip in a bag, part no.
50 1011 7501
Attention: Explosion-proof units without a clip may be brought into
hazardous areas with potentially explosive atmospheres and operated
there only in the special bag with part no. 50 1011 7501.
In addition, the following conditions must be met:
Only a qualified electrician with special knowledge in explosion
protection is allowed to remove or fit the clip of an explosion-proof unit.
The explosion-proof unit without a clip must be put into the special bag
with part no. 50 1011 7501 before bringing it into hazardous areas with
potentially explosive atmospheres.
It must be ensured that the unit without a clip will not be removed from
the bag with part no. 50 1011 7501 while still staying in hazardous areas.
The use of other protective or carrier bags may constitute an explosion
hazard and is therefore not allowed!
Working on the explosion-proof unit
All work on the unit as well as charging and replacing the batteries must
be carried out outside of the hazardous areas.
All modification on the unit as well as any interventions may only be
carried out by the manufacturer or by qualified persons having been
trained and authorised by the manufacturer.
Putting the unit back into operation after interventions
After each intervention into an explosion-proof unit (repair) and before
putting the unit back into operation, in the Federal Republic of Germany an
authorised testing agency must have properly ascertained and
documented that the unit in question meets the requirements of the
german regulations known as BetrSichV as far as essential explosion
protection features are concerned.
Observe any deviating regulations issued by local authorities of the
country where the units are operated.
(BetrSichV = German regulations on safety and health protection when
making working means available and using them for work, on security
when operating systems needing supervision and on the organisation of
in-house industrial safety measures).
FC4 Ex (HS) – Supplementary safety information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk FC4 and is the answer not in the manual?

Funkwerk FC4 Specifications

General IconGeneral
BrandFunkwerk
ModelFC4
CategoryHandsets
LanguageEnglish

Related product manuals