Appendix 2. Message List
AP2-4
5. Notice 9005: (ADE) EL motor: Short circuit detected.
The status for this error is constantly confirmed at an interval of 3 seconds.
This message will be output when the EL motor is being short-circuited with the
power source or when the EL motor is damaged. Please confirm the connection for
the ATB Module and the EL motor. It may also imply a failure in the ATB Module or
in the EL motor. If it is a failure in the ATB Module, replace the Front end Module
(ATB & LNA).
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
6. Notice 9006:(ADE) EL motor: Short detected.
The status for this error is constantly confirmed at an interval of 3 seconds.
This message will be output when the EL motor is being short-circuited with the
GND or when the EL motor is damaged. Please confirm the connection for the ATB
Module and the EL motor. It may also imply a failure in the ATB Module or in the EL
motor. If it is a failure in the ATB Module, replace the Front end Module (ATB &
LNA).
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
7. Notice 9007: (ADE) EL motor:Undervoltage lockout, overvoltage lockout,
overtemperature, low load current or shorted load.
The status for this error is constantly confirmed at an interval of 3 seconds. This
message will be output when abnormality is detected in the EL motor voltage, current,
or temperature, or when the EL motor is damaged. It will also be output when the EL
motor cable is disconnected.
Please confirm the connection for the ATB Module and the EL motor. It may also
imply a failure in the ATB Module or in the EL motor. If it is a failure in the ATB
Module, replace the Front end Module (ATB & LNA).
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.
8. Notice 9008: (ADE) XEL motor: Short circuit detected.
The status for this error is constantly confirmed at an interval of 3 seconds.
This message will be output when Cross EL motor is being short-circuited with the
power source or when Cross EL motor is damaged. Please confirm the connection for
the ATB Module and the Cross EL motor. It may also imply a failure in the ATB
Module or in the Cross EL motor.
If it is a failure in the ATB Module, replace the Front end Module (ATB & LNA).
Note) If the Antenna is operating in a normal manner, the error may be a false
detection.

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals